                  areas, on which pipes from steels of an increased strength (580 MPa and higher)

                  are  laid, to  maintain  polarization  potentials  at  a  level  not  lower  than  -1.10  V

                  (relative to c.s.e.).

                         The results of the work were implemented during the development of the

                  main  provisions  of  SOU  60.3-30019801-070,  DSTU  N  B  A.3.1-29,  changes

                  No. 1 to DSTU 4219.

                         Scientific novelty of the obtained results.

                         1. For the first time a new scientific approach to the study of the influence

                  of different factors on the regularity of the process of corrosion cracking of steel

                  pipe assortment (on the example of X70 steel) was developed, which is based on

                  modeling  the  peculiarities  of  their  action  in  laboratory  conditions,  which  are

                  identical  to  the  conditions  of  the  main  pipeline  operation,  which  allowed

                  evaluating  the  susceptibility  of  the  steel  to  corrosion  cracking  under  such

                  conditions.

                         2.  A  set  of  factors  was  revealed,  that  cause  degradation  of  polymeric

                  coatings  (in  particular,  of  a  tape  one)  applied  to  pipe  steel  during  cathodic

                  protection, namely: presence of defect in the coating, its contact with a corrosive

                  environment  and  cathodic  polarization.  It  was  shown  that  an  increase  in

                                                      о
                                           о
                  temperature from 20  С to 50  С accelerates this process, which continues its
                  development over time. After 2.5 months of contacting with the environment,

                  the primer layer of tape coating is exposed to degradation, which is confirmed

                  by the appearance of bands of inorganic fillers – calcium carbonate and talc in

                  the infrared spectra. The properties of polyethylene tape do not change during


                  the mentioned period. Presence of destruction products of the primer layer in the
                  test solution improves the susceptibility of X70 steel to corrosion cracking.


                         3. It was for the first time determined, that under the conditions of a long-
                  term  action  of  metal  deformation  in  a  model  soil  electrolyte  at  a  cathodic


                  polarization  at  a  potential  of  -1.0  V,  for  X70  steel  subsurface  corrosion  is
                  inherent, and for X80 intergranular fracture is typical, caused by the hydrogen


                  penetration into the metal. The rate of propagation of corrosion cracking in X80
   8   9   10   11   12   13   14   15   16   17   18